Skip to main content

Power Generation Equipment

Diesel Generator

Generator-50Hz

  • Rated output: 2 to 2,000kW/2 to 2,500kVA
  • Rated voltage: L-N 110 to 277V, L-L 220 to 480V
  • Rated frequency: 50/60Hz
  • Powered by reliable engines
  • Branded alternator
  • Open type, silent type, or super silent type generator
  • ISO, CE certified
  • High output
  • Compact and light weight
  • High level of trust in the global market

 

Learn More

Uninterruptible Power Supply (UPS)

EA660 50-600 KVA

  • High efficiency 96.5%
  • High power factor (>o.99) and THDi <3%
  • Power flexibility from 50 – 600 kW
  • High MTBF and low MTTR
  • High adaptability
  • Self-aging function, easy debugging and test on site
  • Modular hot-swappable & scalability
  • DSP digital control technology

EA890 80-500 KVA

  • High efficiency even at light loads
  • High power factor (>0.99) and low THDi
  • Power flexibility from 80 – 500 kW
  • High MTBF and Low MTTR
  • Strong mixed load capacity and high overload capacity
  • Batteries are connected directly to the bus, improving the impact resistance of UPS output
  • Online double-conversion with DSP control

EA990 Super 200-1200 KVA

  • High efficiency up to 96.8%
  • Input power factor up to 0.99, THDi <3%
  • Power flexibility from 200 – 1200 kW
  • Online double conversion architecture with strong load capacity
  • Self-aging function to simplify debugging and test on site
  • Share battery pack in parallel operation, saving user’s battery cost
  • Multi-DSP design that ensures fast and reliable control and switching

Load Bank

2000 kw Resistive Load Bank

with Generator Tester for Generator Testing

  • Type of load: Resistive, PF = 1.0
  • Rated testing voltage: AC 3P4W, 110-480 VAC
  • Rated frequency: 50/60 Hz
  • Testing capacity: from 0kw to the max
  • Parameter measuring accuracy grade: 0.3
  • Load control accuracy: ± 5%
  • Protections: Over heating, cooling fans failure, and over load

800 kw Resistive load bank

for Generator Testing

  • Type of load: Resistive, PF = 1.0
  • Rated testing voltage: 110-480 VAC
  • Rated frequency: 50/60 Hz
  • Testing capacity: from 0kw to the max
  • Parameter measuring accuracy grade: 0.5
  • Load control accuracy: ± 3%
  • Protections: Over heating, cooling fans failure, and over load

125-2500 kva Inductive Load Bank

  • Type of load: Inductive, PF = 1.0
  • Rated testing voltage: AC 3P4W, 110-480 VAC
  • Rated frequency: 50/60 Hz
  • Testing capacity: 125-2500 kva
  • Parameter measuring accuracy grade: 0.5
  • Load control accuracy: ± 3%
  • Protections: Over heating, cooling fans failure, and over load

1250 kva Resistive and Inductive

Load Bank with Generator Tester

  • Type of load: Resistive, PF = 1.0
  • Rated testing voltage: AC 3P4W, 110-480V
  • Rated frequency: 50/60 Hz
  • Testing capacity: from 0kw to the max
  • Parameter measuring accuracy grade: 0.3
  • Load control accuracy: ± 5%
  • Protections: Over heating, cooling fans failure, and over load

Frequency Converter

  • Frequency converters and variable frequency drives (VFD) are widely used across different industries, from utility and renewable energy to aerospace and defense.
  • AC power sources and frequency converters are used to convert fixed frequency (50 hertz, 60 Hz), fixed voltage (110V, 120V, 208V, 220V, 230V, 240V, 380V, 400V, 440V, 480V, etc.) to variable frequency (50Hz/60Hz or 400 Hz adjustable) and variable voltage (adjustable) with pure sine wave output to comply with different power requirements.